UniDEAE-30S Weak Anion Exchange Chromatography Resin
NanoMicro UniDEAE-30S weak anion exchange chromatography resin features a polymer matrix that is surface-modified with hydrophilic groups before ion exchange ligands are coupled. This design provides excellent biocompatibility and physicochemical stability for bioactive macromolecules, significantly improving purification efficiency. It is ideally suited for the purification of small biomolecules such as small proteins, peptides, nucleic acids, and antibiotics.
UniDEAE-30S utilizes a hydrophilic surface modification, offering low non-specific binding, high resolution for small molecules, and high binding capacity. Key technical parameters are listed below:
Performance Specifications
| Product Model | UniDEAE-30S |
| Separation Principle | Weak anion exchange |
| Matrix | Polymethacrylate (PMMA) |
| Particle Size | 36 μm |
| Ligand | -CH2CH2N(CH2CH3)2 |
| Ligand Density | ~0.23 meq·mL-1 |
| Maximum Pressure | 1.0 MPa |
| CIP (Clean-in-Place) | 0.5 M NaOH |
| Recommended Flow Rate | 50-300 cm/h |
| pH Stability | 2~12 |
| Chemical Stability | Compatible with all commonly used buffers, 1 M acetic acid, 1 M sodium hydroxide, 1 M hydrochloric acid, 70% ethanol, 30% isopropanol, 30% acetonitrile, 1% SDS, 6 M guanidine hydrochloride, 8 M urea, and other common organic solvents; avoid contact with strong oxidizing agents. |
| Operating Temperature | 4-30 ℃ |
| Storage Conditions | 20% ethanol, 4-25 ℃ |
Ordering Information
| Product | Package Size | Catalog # |
| UniDEAE-30S | 30 mL | 04023-030050-2030 |
| 50 mL | 04023-030050-2050 | |
| 100 mL | 04023-030050-2100 | |
| 300 mL | 04023-030050-2300 | |
| 500 mL | 04023-030050-2500 | |
| 1 L | 04023-030050-1001 | |
| 5 L | 04023-030050-1005 | |
| 10 L | 04023-030050-1010 | |
| 50 L | 04023-030050-1050 | |
| 100 L | 04023-030050-1100 |