NW Rose Series Gel Filtration Pre-packed Columns
-
NW Super Series Gel Filtration Pre-packed Columns
-
NW Dex Series Gel Filtration Pre-packed Columns
-
NW Rose Plus HP Series HIC Pre-packed Columns
-
UniHR Butyl HIC Pre-packed Column
-
UniHR Phenyl HIC Pre-packed Column
-
NanoHR Series HIC Pre-packed Columns
-
NW Rose Plus Series Multimodal Chromatography Pre-packed Columns
-
NW Rose Plus HP Series Multimodal Pre-packed Chromatography Columns
-
NW Rose Viral Multimodal Pre-packed Column
-
NM90Agarose Series Multimodal Pre-packed Columns
-
UniMSP Series Multimodal Pre-packed Columns
-
Uni Series Multimodal Pre-packed Columns
-
NanoGel Series Ion Exchange Pre-packed Columns
-
Nano Series Ion Exchange Pre-packed Columns
-
UniGel Series Ion Exchange Pre-packed Columns
-
Uni Series Ion Exchange Pre-packed Columns
-
NMGel Series Ion Exchange Pre-packed Columns
-
UniCore Series Ion Exchange Pre-packed Columns
-
NW Rose FF Series Ion Exchange Pre-packed Columns
-
NW Rose HP Series Ion Exchange Pre-packed Columns
-
NW Rose XL Series Ion Exchange Pre-packed Columns
-
NW Rose (BB) Ion Exchange Pre-packed Columns
-
NW Rose Plus Series Ion Exchange Pre-packed Columns
-
NW Rose Plus HP Series Ion Exchange Pre-packed Columns
-
NW Rose Plus XP Series Ion Exchange Pre-packed Columns
-
Protein A Affinity Chromatography Pre-packed Columns
-
Protein G Affinity Chromatography Pre-packed Columns
-
Protein L Affinity Chromatography Pre-packed Column
-
IMAC Affinity Chromatography Pre-packed Columns
-
Nucleic Acid Affinity Pre-packed Columns
-
Phenylboronic Acid Affinity Pre-packed Column
-
Heparin Affinity Pre-packed Columns
-
Endotoxin Affinity Chromatography Pre-packed Columns
-
Small-Tag Affinity Pre-packed Columns
-
Anti-A Anti-B Affinity Chromatography Pre-packed Column
-
Low-Pressure Pilot-Scale Columns - NmPILOT Plus Series
-
Medium-Pressure Pilot-Scale Prep Columns - NmPILOT Series
-
Connect Glass Preparation Columns - EZPacking Series Quick
-
Low-Pressure Glass Jacketed Preparative Column - NmXK Series
-
Pressure Glass Process Development Columns - NmVALID Pro Series Medium
-
PP Column - NmPREP Series
-
PP Column - NmSCREEN Series
-
PP Column - NmTRAP Series
Phenylboronic Acid Affinity Pre-packed Column
Phenylboronic acid affinity chromatography leverages the covalent coordination between boronic acid and cis-diol compounds for separation and purification. Under alkaline conditions, boronic acid groups form stable five-membered ring complexes with cis-diol structures, enabling specific adsorption of glycosylated proteins. Under acidic conditions, the complexes dissociate, and glycoproteins are eluted. Additionally, boronate affinity media can be used for the purification of cis-diol-containing compounds such as nucleosides, nucleotides, and saccharides.
Product Description
NanoMicro phenylboronic acid pre-packed columns utilize monodisperse rigid hydrophilic PMMA matrices. High ligand density delivers high dynamic binding capacity. Leveraging the specific reversible binding between phenylboronic acid and cis-diols, our columns efficiently purify plasmids, glycoproteins, and nucleoside polysaccharides. They offer high flow rates with low back pressure, resistance to repeated alkaline CIP, minimal ligand leakage, and low non-specific adsorption. Mild elution conditions protect nucleic acid/glycoprotein integrity. Our fully domestic, self-developed industrial chain is tailored for CGT industrial-scale production.
Performance Specifications

Ordering Information
| Prepacked column specifications | Cat. No. | Prepacked column specifications | Cat. No. |
| NmTRAP 1mL, UniPB-80L | 77221-04000-080001 | NmTRAP 1mL, UniPB-80 | 77221-04000-080002 |
| NmTRAP 5mL, UniPB-80L | 16255-04000-080001 | NmTRAP 5mL, UniPB-80 | 16255-04000-080002 |
| NmSCREEN 4.7mL, UniPB-80L | 77105-04000-080001 | NmSCREEN 4.7mL, UniPB-80 | 77105-04000-080002 |
| NmPREP 16/100, UniPB-80L | 16103-04000-080001 | NmPREP 16/100, UniPB-80 | 16103-04000-080002 |
| NmPREP 26/100, UniPB-80L | 26153-04000-080001 | NmPREP 26/100, UniPB-80 | 26153-04000-080002 |
| NmVALID 8/100, UniPB-80L | 08101-04000-080001 | NmVALID 8/100, UniPB-80 | 08101-04000-080002 |
| NmVALID 8/200, UniPB-80L | 08201-04000-080001 | NmVALID 8/200, UniPB-80 | 08201-04000-080002 |
| NmVALID 11/100, UniPB-80L | 11101-04000-080001 | NmVALID 11/100, UniPB-80 | 11101-04000-080002 |
| NmVALID 11/200, UniPB-80L | 11201-04000-080001 | NmVALID 11/200, UniPB-80 | 11201-04000-080002 |
| NmVALID 16/100, UniPB-80L | 16106-04000-080001 | NmVALID 16/100, UniPB-80 | 16106-04000-080002 |
| NmVALID 16/200, UniPB-80L | 16206-04000-080001 | NmVALID 16/200, UniPB-80 | 16206-04000-080002 |
| NmVALID 26/100, UniPB-80L | 26106-04000-080001 | NmVALID 26/100, UniPB-80 | 26106-04000-080002 |
| NmVALID 26/200, UniPB-80L | 26206-04000-080001 | NmVALID 26/200, UniPB-80 | 26206-04000-080002 |
| NmVALID 35/100, UniPB-80L | 35101-04000-080001 | NmVALID 35/100, UniPB-80 | 35101-04000-080002 |
| NmVALID 35/200, UniPB-80L | 35201-04000-080001 | NmVALID 35/200, UniPB-80 | 35201-04000-080002 |
| NmVALID 50/100, UniPB-80L | 50106-04000-080001 | NmVALID 50/100, UniPB-80 | 50106-04000-080002 |
| NmVALID 50/200, UniPB-80L | 50206-04000-080001 | NmVALID 50/200, UniPB-80 | 50206-04000-080002 |
| NmPILOT 70/100,UniPB-80L | 70105-04000-080001 | NmPILOT 70/100,UniPB-80 | 70105-04000-080002 |
| NmPILOT 70/200,UniPB-80L | 70205-04000-080001 | NmPILOT 70/200,UniPB-80 | 70205-04000-080002 |
| NmPILOT 100/100,UniPB-80L | 10105-04000-080001 | NmPILOT 100/100,UniPB-80 | 10105-04000-080002 |
| NmPILOT 100/200,UniPB-80L | 10205-04000-080001 | NmPILOT 100/200,UniPB-80 | 10205-04000-080002 |
| NmPILOT 140/100,UniPB-80L | 14105-04000-080001 | NmPILOT 140/100,UniPB-80 | 14105-04000-080002 |
| NmPILOT 140/200,UniPB-80L | 14205-04000-080001 | NmPILOT 140/200,UniPB-80 | 14205-04000-080002 |
| NmPILOT 200/100,UniPB-80L | 20105-04000-080001 | NmPILOT 200/100,UniPB-80 | 20105-04000-080002 |
| NmPILOT 200/200,UniPB-80L | 20205-04000-080001 | NmPILOT 200/200,UniPB-80 | 20205-04000-080002 |